微波EDA网,见证研发工程师的成长!
首页 > 研发问答 > 信号完整性分析 > Cadence Sigrity 仿真分析讨论 > 求助:IBIS转DML出错了啊

求助:IBIS转DML出错了啊

时间:10-02 整理:3721RD 点击:
IBIS文件时官方网页上下载的,用PCB SI软件转为DML格式时,出错了,帮我看看,谢谢!
最后一条ERROR信息:
RUNNING IBISCHK COMMAND: ibischk4 "IBIS\ad9523.ibs"
IBISCHK4 V4.0.1
Checking IBIS\ad9523.ibs for IBIS 3.2 Compatibility...
Errors  : 0
File Passed
END OF IBISCHK COMMAND OUTPUT
READING IBIS FILE IBIS\ad9523.ibs
INFO @line 47 --- Completed PackagedDevice AD9523
INFO @line 450 --- Completed IbisIOCell AD9523_clk_spi
INFO @line 484 --- Completed IbisIOCell AD9523_in_pd
INFO @line 522 --- Completed IbisIOCell AD9523_in_pu_10k
INFO @line 575 --- Completed IbisIOCell AD9523_in_ref
INFO @line 630 --- Completed IbisIOCell AD9523_io_od
INFO @line 963 --- Completed IbisIOCell AD9523_irq_cmos
INFO @line 1608 --- Completed IbisIOCell AD9523_irq_nmos
INFO @line 1939 --- Completed IbisIOCell AD9523_irq_pmos
INFO @line 2270 --- Completed IbisIOCell AD9523_ctrl_io
INFO @line 2917 --- Completed IbisIOCell AD9523_ctrl_tri
INFO @line 3564 --- Completed IbisIOCell AD9523_cmos
INFO @line 4225 --- Completed IbisIOCell AD9523_lvds_3_5ma
INFO @line 4651 --- Completed IbisIOCell AD9523_lvds_7ma
INFO @line 5086 --- Completed IbisIOCell AD9523_pecl
INFO @line 5530 --- Completed IbisIOCell AD9523_term
INFO @line 5541 --- Completed IbisIOCell AD9523_term2
INFO: The following names have been changed to conform to syntax requirements:
OLD NAME                                NEW NAME
AD9523_lvds_3.5ma                       AD9523_lvds_3_5ma
AD9523_mode_out0+                       AD9523_mode_out0_
AD9523_mode_out0-                       AD9523_mode_out0_
AD9523_mode_out1+                       AD9523_mode_out1_
AD9523_mode_out1-                       AD9523_mode_out1_
AD9523_mode_out10+                      AD9523_mode_out10_
AD9523_mode_out10-                      AD9523_mode_out10_
AD9523_mode_out11+                      AD9523_mode_out11_
AD9523_mode_out11-                      AD9523_mode_out11_
AD9523_mode_out12+                      AD9523_mode_out12_
AD9523_mode_out12-                      AD9523_mode_out12_
AD9523_mode_out13+                      AD9523_mode_out13_
AD9523_mode_out13-                      AD9523_mode_out13_
AD9523_mode_out2+                       AD9523_mode_out2_
AD9523_mode_out2-                       AD9523_mode_out2_
AD9523_mode_out3+                       AD9523_mode_out3_
AD9523_mode_out3-                       AD9523_mode_out3_
AD9523_mode_out4+                       AD9523_mode_out4_
AD9523_mode_out4-                       AD9523_mode_out4_
AD9523_mode_out5+                       AD9523_mode_out5_
AD9523_mode_out5-                       AD9523_mode_out5_
AD9523_mode_out6+                       AD9523_mode_out6_
AD9523_mode_out6-                       AD9523_mode_out6_
AD9523_mode_out7+                       AD9523_mode_out7_
AD9523_mode_out7-                       AD9523_mode_out7_
AD9523_mode_out8+                       AD9523_mode_out8_
AD9523_mode_out8-                       AD9523_mode_out8_
AD9523_mode_out9+                       AD9523_mode_out9_
AD9523_mode_out9-                       AD9523_mode_out9_
RUNNING DMLCHECK for IBIS\ad9523.dml
WARNING @line 4689: minimum Rise slew rate exceeds typical Rise slew rate
WARNING @line 4689: minimum Fall slew rate exceeds typical Fall slew rate
WARNING @line 5192: typical Rise slew rate exceeds maximum Rise slew rate
WARNING @line 5842: Missing input threshold for ModelType Input
WARNING @line 5858: Missing input threshold for ModelType Input
WARNING @line 4: AD9523_clk_spi GroundClamp: Overall typical area exceeds overall maximum area
WARNING @line 4: AD9523_clk_spi GroundClamp: Overall minimum area exceeds overall typical area
WARNING @line 4: AD9523_clk_spi GroundClamp: Slope at end is not flat - point added
WARNING @line 326: AD9523_cmos PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 326: AD9523_cmos PowerClamp: Overall minimum area exceeds overall typical area
WARNING @line 326: AD9523_cmos PowerClamp: Slope at end is not flat - point added
WARNING @line 285: AD9523_cmos GroundClamp: Overall typical area exceeds overall maximum area
WARNING @line 285: AD9523_cmos GroundClamp: Overall minimum area exceeds overall typical area
WARNING @line 285: AD9523_cmos GroundClamp: Slope at end is not flat - point added
WARNING @line 59: AD9523_cmos FallingWaveform fall_1 max: Non-monotonic dV = 2.59411 at time 7.575e-010 exceeds 1% of voltage span
WARNING @line 59: TVCurve should asymptotically approach a final value - point added
WARNING @line 1073: AD9523_ctrl_io PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 1024: AD9523_ctrl_io GroundClamp: Overall minimum area exceeds overall typical area
WARNING @line 798: AD9523_ctrl_io FallingWaveform fall_1 max: Non-monotonic dV = 1.758 at time 1.445e-009 exceeds 1% of voltage span
WARNING @line 798: TVCurve should asymptotically approach a final value - point added
WARNING @line 1796: AD9523_ctrl_tri PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 1753: AD9523_ctrl_tri GroundClamp: Overall minimum area exceeds overall typical area
WARNING @line 1527: AD9523_ctrl_tri FallingWaveform fall_1 max: Non-monotonic dV = 1.758 at time 1.445e-009 exceeds 1% of voltage span
WARNING @line 1527: TVCurve should asymptotically approach a final value - point added
WARNING @line 2241: AD9523_in_pd GroundClamp: Overall typical area exceeds overall maximum area
WARNING @line 2241: AD9523_in_pd GroundClamp: Slope at end is not flat - point added
WARNING @line 2330: AD9523_in_pu_10k PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 2330: AD9523_in_pu_10k PowerClamp: Overall minimum area exceeds overall typical area
WARNING @line 2290: AD9523_in_pu_10k GroundClamp: Overall typical area exceeds overall maximum area
WARNING @line 2290: AD9523_in_pu_10k GroundClamp: Overall minimum area exceeds overall typical area
WARNING @line 2290: AD9523_in_pu_10k GroundClamp: Slope at end is not flat - point added
WARNING @line 2407: AD9523_in_ref PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 2407: AD9523_in_ref PowerClamp: Overall minimum area exceeds overall typical area
WARNING @line 2368: AD9523_in_ref GroundClamp: Overall typical area exceeds overall maximum area
WARNING @line 2368: AD9523_in_ref GroundClamp: Slope at end is not flat - point added
WARNING @line 2568: AD9523_io_od GroundClamp: Overall minimum area exceeds overall typical area
WARNING @line 2724: TVCurve should asymptotically approach a final value - point added
WARNING @line 2455: TVCurve should asymptotically approach a final value - point added
WARNING @line 3120: AD9523_irq_cmos PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 3077: AD9523_irq_cmos GroundClamp: Overall minimum area exceeds overall typical area
WARNING @line 2851: AD9523_irq_cmos FallingWaveform fall_1 max: Non-monotonic dV = 1.758 at time 1.445e-009 exceeds 1% of voltage span
WARNING @line 2851: TVCurve should asymptotically approach a final value - point added
WARNING @line 3687: AD9523_irq_nmos GroundClamp: Overall minimum area exceeds overall typical area
WARNING @line 3837: TVCurve should asymptotically approach a final value - point added
WARNING @line 3574: TVCurve should asymptotically approach a final value - point added
WARNING @line 4083: AD9523_irq_pmos PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 3964: AD9523_irq_pmos FallingWaveform fall_1 max: Non-monotonic dV = 1.758 at time 1.445e-009 exceeds 1% of voltage span
WARNING @line 3964: TVCurve should asymptotically approach a final value - point added
WARNING @line 4508: AD9523_lvds_3_5ma PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 4508: AD9523_lvds_3_5ma PowerClamp: Overall minimum area exceeds overall typical area
WARNING @line 4508: AD9523_lvds_3_5ma PowerClamp: Slope at end is not flat - point added
WARNING @line 4712: AD9523_lvds_3_5ma RisingWaveform rise_1 max: Non-monotonic dV = 0.006 at time 1.86e-010 exceeds 1% of voltage span
WARNING @line 4712: TVCurve should asymptotically approach a final value - point added
WARNING @line 4345: TVCurve should asymptotically approach a final value - point added
WARNING @line 5002: AD9523_lvds_7ma PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 5002: AD9523_lvds_7ma PowerClamp: Overall minimum area exceeds overall typical area
WARNING @line 5002: AD9523_lvds_7ma PowerClamp: Slope at end is not flat - point added
WARNING @line 4952: AD9523_lvds_7ma GroundClamp: Overall minimum area exceeds overall typical area
WARNING @line 5215: TVCurve should asymptotically approach a final value - point added
WARNING @line 4839: TVCurve should asymptotically approach a final value - point added
WARNING @line 5506: AD9523_pecl PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 5506: AD9523_pecl PowerClamp: Overall minimum area exceeds overall typical area
WARNING @line 5506: AD9523_pecl PowerClamp: Slope at end is not flat - point added
WARNING @line 5725: TVCurve should asymptotically approach a final value - point added
WARNING @line 5342: AD9523_pecl FallingWaveform fall_1 typ: Non-monotonic dV = 1.10206 at time 7.46e-010 exceeds 1% of voltage span
WARNING @line 5342: TVCurve should asymptotically approach a final value - point added
WARNING @line 5900: AD9523_term2 PowerClamp: Overall typical area exceeds overall maximum area
WARNING @line 5900: AD9523_term2 PowerClamp: Overall minimum area exceeds overall typical area
WARNING @line 5900: AD9523_term2 PowerClamp: Slope at end is not flat - point added
WARNING @line 5859: AD9523_term2 GroundClamp: Overall typical area exceeds overall maximum area
WARNING @line 5859: AD9523_term2 GroundClamp: Overall minimum area exceeds overall typical area
WARNING @line 5859: AD9523_term2 GroundClamp: Slope at end is not flat - point added
ERROR @line 6775: Syntax error after parsing the token <cmos out 0110,0111,1000,1011,1100,1101 > :
    The previous token began on line 6775 and was <cmos out 0110,0111,1000,1011,1100,1101 >
Translation failed due to DMLCHECK errors.
Output saved as IBIS\ad9523.dml.txt for examination.

可能是中文文件名的原因吧,我的就是

最好把IBIS文件也上传了!

Copyright © 2017-2020 微波EDA网 版权所有

网站地图

Top