时间:10-02 整理:3721RD 点击:
allegro BRD 文件导入 Hyplynx 时,不成功,Log 如下:
Job Name         : D:\163
Input File Name  : D:\163.brd
HYP File Name    : D:\163.hyp
REF File Name    : D:\163.ref
Log File Name    : D:\163.log
Err File Name    : D:\163.err
Control File     : C:\MentorGraphics\PADSVX.1.2\SDD_HOME\hyperlynx\control_hyp.txt
info : Extracting Allegro Board Database
ERROR: Could not run Cadance Allegro utility: extracta.
ERROR: mode argument is invalid.
ERROR: Could not convert file 'D:\163.brd'
       to file '"D:\163.a_b"'.
The Allegro-to-HyperLynx translator requires Cadence's ASCII-out
utility, EXTRACTA, as well as the Allegro directory structure.
This can be found in any Allegro installation including the
Allegro Physical Viewer, which is available from Cadence.
(The free download - Allegro FREE Physical Viewer - will not
work for this purpose.)
HyperLynx Online Help includes instructions for operation of a
HyperLynx utility that works with Cadence's Extracta, and that can
be provided to your PCB service bureau.  This application is allegro2hyp;
and you can read more on this subject by navigating to 'Cadence Allegro
Translator' topic in the HyperLynx Help system.
info : Error with extraction
求大师指点迷津,感谢

allegro 17画的吧

添加一个系统变量CDSROOT=C:\Cadence\SPB_17.2

同樣問題 已設定系統變量仍無法轉檔

重装的系统

小编现在解决了吗,我遇到了同样的问题,一直没办法解决